Michaelis Furnace Systems: Moved Bed Furnace Type Cd-V

Main data
Kind of waste
  • solid
  • paste-like up to 40% moisture content
  • Incineration of liquid waste is possible to a limited extent
Amount of waste (kg/h) 200 - 1.000
Calorific value of waste (MJ/kg) 1 - 45
Density of waste (kg/m3) 50 - 1250

Features:

Technical data
Type Cd 7V Cd 10V Cd 11V Cd 12V Cd 13V
Capacity (kg/h) 200 400 600 800 1000
Thermal power (kW) 700 1400 2100 2800 3500
Main combustion chamber
Temperature (°C) 800 - 1200
Residence time of waste (Minutes) 30 - 45
Required space L x W x H (m) L 2,6
W 2,2
H 2,5
 
L 3,0
W 2,2
H 2,5
 
L 3,4
W 2,3
H 2,6
 
L 3,8
W 2,3
H 2,6
 
L 4,2
W 2,6
H 3,0
 
Postcombustion chamber
Temperature (°C) 800 - 1200
Residence time of flue gas (Seconds) 1 - 2
Required space d (m); H (m)
(d = Diameter)
d 2,0
H 3,3
 
d 2,3
H 4,0
 
d 2,5
H 4,4
 
d 2,8
H 4,4
 
d 3,0
H 4,6
 
  1. Each incineration system will be adapted to the local requirements by Michaelis.
    The data indicated on the table are reference values.
     
  2. The data are calculated with a calorific value of 12.500 kJ/kg and a moisture content less than 10%.
     
  3. With the composition of the waste the indicated data will change.